SharePoint and Nintex workflows failing on start pt.2 **FULLY RESOLVED**

It’s back again…a few months ago a wrote about my experiences with workflows failing on start after a .NET security update that was applied. You can read that post here:

SharePoint and Nintex workflows failing on start

Recently, the same .NET security update was applied to our SharePoint 2010 farm, which in turn caused the failing on start error to present itself again across all the workflows in the farm.

After identifing the issue soon after the update was applied, we decided to follow the same tact as before and roll back the patches, restart the servers and re-test the workflows – However, this time the results were different.

What was different?

Previously, rolling back the security update and any other patches added during this time, plus restarting the servers “fixed” the issue. This time, the same process did not yeald the same results and the workflows were still broken.

After performing the steps above, we observed that standard SharePoint workflows with a pause started to run sucessfully again, but Nintex workflows with a pause step either failed on start, or completed but errored after the pause step and sent an error notification.

Example 1 of nintex workflow with pause step failing on start
Example 2 of nintex workflow with pause step erroring, but completing

How we fixed it…

So this time we followed the updated step-by-step guide provided below on how to update the web.config files and OWS timer files via Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1 PowerShell script on the SharePoint Application server.


https://blogs.msdn.microsoft.com/rodneyviana/2018/10/12/step-by-step-video-on-how-to-fix-the-sharepoint-workflow/

We ran the script as recommended, which re-added the assemblies and dependancies to the OWSTimer config file and the web.config files on associated web servers and this in fact fixed the issue! As the script does an IIS reset/ Timer Job recycle we didnt even need to restart the servers!

I hope the that tidbit regarding the nintex workflow pauses helps someone else 🙂

Advertisement

SharePoint and Nintex workflows failing on start after .NET security update

Updated


I’ve wrote part two on this issue with my full resolution steps here:

SharePoint and Nintex workflows failing on start – part two


The problem


I had this issue myself in the last week where EVERY SINGLE workflow across the farm on premise stopped working. SharePoint Designer and Nintex workflows all reported “Failed to start” when triggered to run.

The workflows stopped working due to a series of .NET security updates Microsoft released in September 2018. Microsoft released a public KB article on this – with resolution steps which can be found below:

But also this msdn blog post contains all the solution scripts and steps that includes Nintex workflows also (transcript below):

I noticed shortly after the fix was implemented that some of my SharePoint designer workflows were exhibiting odd behaviour. For example the screenshot below shows a SharePoint desinger workflow that previously worked without issue or errors in the history after the fix was applied:

Someone on reddit had already spotted this which drew my attention to the common issue, this only presents itself for workflows with pause steps!

I will update this post with my findings once this latest fix is applied.

Symptom

After applying .NET Security Only patch to resolve CVE-2018-8421 (Remote Code Execution Vulnerability) , all SharePoint out of the box Workflows fail to execute and the log will show an error like this:

09/13/2018 01:59:07.57 w3wp.exe (0x1868) 0x22FC SharePoint Foundation Workflow Infrastructure 72fs Unexpected RunWorkflow: Microsoft.SharePoint.SPException: <Error><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″ Text=”Type System.CodeDom.CodeBinaryOperatorExpression is not marked as authorized in the application configuration file.” /><CompilerError Line=”-1″ Column=”-1″…

The error suggest that System.CodeDom.CodeBinaryOperatorExpression is not in the authorized types.

Cause

Workflow Foundation (WF) will only run workflows when all the dependent types and assemblies are authorized in the .NET config file (or added explicitly via code) under this tree:

<configuration>

<System.Workflow.ComponentModel.WorkflowCompiler>

<authorizedTypes>

<targetFx>

However, after the update, the following lines are necessary for SharePoint 2013 and beyond:

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeBinaryOperatorExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePrimitiveExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodInvokeExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeFieldReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeThisReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePropertyReferenceExpression” Authorized=”True” />

And for SharePoint 2007 and 2010, use these lines:

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeBinaryOperatorExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePrimitiveExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodInvokeExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeFieldReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeThisReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePropertyReferenceExpression” Authorized=”True” />

Solution

The solution is to add explicitly the types to all web applications’ web.config:

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeBinaryOperatorExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePrimitiveExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodInvokeExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeFieldReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeThisReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePropertyReferenceExpression” Authorized=”True” />

Or (for SharePoint 2007 and 2010):

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeBinaryOperatorExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePrimitiveExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodInvokeExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeMethodReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeFieldReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeThisReferenceExpression” Authorized=”True” />

<authorizedType Assembly=”System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodePropertyReferenceExpression” Authorized=”True” />

Please notice that sometimes SharePoint Timer Service (SPTimerV4) runs workflows. If you notice that the application showing the error is ULS logs in OWSTIMER.EXE, you should also include the authorized types in [SharePoint Hive Folder]\bin\OWSTIMER.EXE.config. The Hive Folder will change by version of SharePoint. For SharePoint 2016, it is normally at c:\program files\common files\microsoft shared\web server extensions\16. For 2013, at c:\program files\common files\microsoft shared\web server extensions\15.

Additional Information

My colleague Joe Rodgers, who is Sr. PFE, put together this PowerShell script: https://gist.github.com/joerodgers/2302b394796c865818839d843bae2dad

There are two scripts. Normally, the only necessary script is:

Add-CodeDomAuthorizedType.ps1

Uncomment this line to make the changes:

Add-CodeDomAuthorizedType

If you have Nintex workflows you should run like this:

Add-CodeDomAuthorizedType -IncludeNintexWorkflow

To undo the changes, run:

Remove-CodeDomAuthorizedType

The script needs to run only once on any WFE. All web.config files related to SharePoint on all servers will be modified. New web applications created after that will also include the changes. Even if a new WFE is added to the farm, the entries will also be included in web.config. The change is a permanent requirement from now on since the WF patch. You do not need to undo the change before applying the SharePoint patch addressing it.

There is a second script to update OWSTIMER.exe.config. This one should only run if you see the symptoms in ULS logs with process OWSTIMER.EXE. Otherwise, you do not need to update. if you have the problem though, you need to rerun the script if a new machine is added to the farm. No line needs to be uncommented for this one. The script name is:

Add-CodeDomAuthorizedTypeToOWSTimerConfig.ps1

Note

Microsoft is aware of this issue and patches for SharePoint 2010, 2013 and 2016 are being worked as of 9/17/2018. I will update when we have an ETA. I had confirmation from the product team on 9/18/2018 that this information and solution on this post is in the line with the future patch and it is the recommended action plan until the patch is out. If anything change, I will update the post.

Note 2

Some people using third-party workflows (like Nintex) need to also include this:

<authorizedType Assembly=”System, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089″ NameSpace=”System.CodeDom” TypeName=”CodeTypeReferenceExpression” Authorized=”True” />

Using the script, you need to add to the line defining types (line 24):

CodeTypeReferenceExpression

Example:
$typeNames = @( CodeBinaryOperatorExpression, CodePrimitiveExpression, CodeMethodInvokeExpression, CodeMethodReferenceExpression, CodeFieldReferenceExpression,CodeThisReferenceExpression, CodePropertyReferenceExpression“, “CodeTypeReferenceExpression”)

Note 3

Joe updated his script to add a switch for Nintex workflows.

Call this way to include the extra type required by Nintex:

Add-CodeDomAuthorizedType -IncludeNintexWorkflow

(all credit to Rodney Viana for this information)